Live › vulnerability › CVE-2026-99091
Go to dashboardWhen the Bluetooth adapter is powered off, pending management commands such as Start Discovery are answered with status 0x00 (Success) instead of Not Powered or Invalid Index, because the wrong value is read from a pointer. The result is a wrong status to userspace, which can crash bluetoothd on a zero-length success reply.
Summary written from the sources below. Check the originals before acting.
First seen by InfraStack 2026-10-26 16:02 UTC. All times on this page are UTC.
Systems running Linux with Bluetooth adapters that use the mgmt interface, such as desktops and laptops running bluetoothd. The sources describe a crash in userspace on a zero-length success reply, and the sources do not say which kernel versions are affected or whether remote attackers can trigger it.
No product ranges from the sources yet.
Each row is the first time that source carried this signal. The analyst’s rows are its own findings.
In the Linux kernel, the following vulnerability has been resolved:
Bluetooth: MGMT: Fix status of pending commands flushed on power off
cmd_complete_rsp() receives a struct cmd_lookup and, for a pending command that has no cmd_complete callback, falls through to cmd_status_rsp(cmd, data). cmd_status_rsp() reads data as a u8 *, so the status sent comes from the first byte of match->sk's representation, not from match->mgmt_status.
commit f53e1c9c726d ("Bluetooth: MGMT: Fix possible crash on mgmt_index_removed") changed the callers' data from &status to &match and updated the cmd_complete branch to match->mgmt_status, but left the fall-through passing data unchanged.
In mgmt_index_removed() match->sk is NULL, so every such command is answered with status 0x00 (Success) instead of MGMT_STATUS_INVALID_INDEX. In __mgmt_power_off() it is NULL too, unless a Set Powered command was pending: then settings_rsp() has stored that command's socket in match->sk, and the byte sent comes from the socket pointer. Either way the status the caller set, MGMT_STATUS_NOT_POWERED (or MGMT_STATUS_INVALID_INDEX when the device is being unregistered), is lost.
Pass the status the callers set.
This was seen on a QCA9377 laptop: bluetoothd's Start Discovery, pending when the adapter was powered off, was answered with Command Status 0x00 and no parameters, and bluetoothd 5.72 crashed on the zero-length success. BlueZ master has since added the length check on that path ("adapter: Fix crash on short start discovery reply", BlueZ a734b06059cb), but userspace should still be told Not Powered, not Success.
Tested on Ubuntu 7.0.0-31 with a virtual controller (hci_vhci): power off is held in HCI Write Scan Enable while a Start Discovery is submitted, and the flush answers it with status 0x00 before this change and 0x0f (Not Powered) after.